8 Art.3121 Intercom made from white ABS shockproof plastic with “door-open” and “service” push buttons. It has electronic call tone with the volume

Strona 3

9Art.3126 As the Art.3125 but with timed privacy, the duration depends on the JP2 settings: Position Duration A about 8 minutes B ¼ hour C ½ hour D

Strona 4

10 POWER SUPPLIES ALIMENTATORI INSTALLATION Install the power supply as follows, also referring to the General Directions for Installation on pag

Strona 5

11ENSLAVEMENT RELAY MODULES MODULI RELÈ DI ASSERVIMENTO ART.506N Enslavement Relay (230Vac 5A max) enables the control of stair lights or other

Strona 6

12 ART.509N It incorporates a modulated tone generator plus a system reset circuit. It is necessary on “4+1” audio door entry systems with privacy o

Strona 7 - INTRODUZIONE

13 - The relays in the switch have two positions (“A” and “B”). To enable the switching to one of the two positions it is necessary to draw a curren

Strona 8 - CITOFONI

14 800 SERIES MODULAR SYSTEM SISTEMA MODULARE SERIE 800 Videx manufacture a range of modular push button panels that allow for an easy and cost effe

Strona 9

15Terminals: 2 Speech output. 13Vac power input for the LEDs. 3 +8Vdc power input. 1 Speech input. 4 Speech ground. Ground (0V) for 13Vac. P2 Call

Strona 10

16 EXTENSION MODULES MODULI PULSANTIERA Art.842, 843, 844, 845 These modules have only call buttons and the lamp for illuminating the name plates.

Strona 11

17ACCESS CONTROL MODULES MODULI PER IL CONTROLLO ACCESSI Art.VX800N-2,VX800N-2L,VX800N-3,VX800N-3L,VX900N-2,VX900N-2L These modules have a toug

Strona 13

18 Terminals: - Ground 12 12Vdc power supply RK Data Signal LR Red LED signal LG Green LED signal Access control systems operating by proximity key

Strona 14 - SCAMBIATORI DI INGRESSI

19 Art. Modules Columns Dimensions (mm) Moduli Colonne Dimensioni (mm) 861A 1 1 135x166 1 1 135x166 862A 2 1 135x286 2 1 135x286 863A 3 1 135x406 3

Strona 15

20 EXAMPLES OF MODULE COMBINATIONS (1 TO 42 BUTTONS) Below are examples of how to combine modules to get the required number of push buttons. The sp

Strona 16 - SISTEMA MODULARE SERIE 800

21NOTES AND SUGGESTIONS FOR A CORRECT INSTALLATION NOTE E SUGGERIMENTI PER UNA CORRETTA INSTALLAZIONE On the previous page are shown some examples b

Strona 17

22 2 MODULES OUTDOOR STATION MOUNTING PROCEDURE Flush mounting (Fig.5) a. Mount the box (1) at 165-170 cm. from ground level (as shown on fig.4);

Strona 18

23INSTALLING ACCESSORIES AND ADDITIONAL COMPONENTS INSTALLAZIONE ACCESSORI E COMPONENTI ADDIZIONALI

Strona 20

25GENERAL DIRECTIONS FOR INSTALLATION NORME GENERALI DI INSTALLAZIONE In order to achieve the best results from the schematics described it is neces

Strona 21

26 TROUBLESHOOTING GUIDE Depending on fault found, carry out the following preliminary checks: - Measure the mains power between terminals 230V (or

Strona 22

27The electric lock does not work: - Pressing the “door open” push button, check that the voltage on the electric lock terminals is higher than 10Va

Strona 23 - INSTALLAZIONE

1INDEX INDEX ... 1 INTRODUCTION ...

Strona 24

28 Feedback (Larsen effect): - Microphone of the speaker unit or of the handset out of housing; - Adjust volumes (may be to high); - Intercom defect

Strona 25

29No speech between extensions: - Wires “A” or “B” broken or in short circuit; - Call made without lifting the handset; - Art.510N defective. No sp

Strona 26

30 NOTES NOTE

Strona 27 - TESTING INSTALLATION

31WIRING DIAGRAMS SCHEMI APPLICATIVI Here are some examples of installations for “3+1” without privacy of speech, “4+1” and “1+1” audio door entry s

Strona 28

32 “3+1” AUDIO DOOR ENTRY SYSTEMS SISTEMI CITOFONICI “3+1” ONE ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “n” USERS This diagram shows a basic “3+1” syst

Strona 30

34 TWO ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one shown on page 32 but it has two entrances. The Art.502N (audio e

Strona 32 - NOTES NOTE

36 THREE OR MORE ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one shown on page 32 but is for three or more entrances. T

Strona 34 - SISTEMI CITOFONICI “3+1”

2 INDICE INDICE ... 2 INTRODUZIONE...

Strona 35

38 ONE ENTRANCE WITH PROXIMITY KEY READER AUDIO DOOR ENTRY SYSTEM FOR “20” USERS (FIG.1) The figure 1 diagram shows the standard system on page 32 w

Strona 37

40 “4+1” AUDIO DOOR ENTRY SYSTEMS WITH PRIVACY OF SPEECH AND FULL LOCK SISTEMI CITOFONICI “4+1” CON SEGRETO DI CONVERSAZIONE E BLOCCO SERRATURA O

Strona 39

42 TWO ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one on page 40 but has two entrances. The Art.502N (audio entrances

Strona 41

44 THREE OR MORE ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one shown on page 40 but has three or more entrances. A c

Strona 43

46 “1+1” AUDIO DOOR ENTRY SYSTEMS SISTEMI CITOFONICI “1+1” ONE ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The “1+1” system, based on a common w

Strona 45

3TECHNICAL MANUAL DOOR PHONE SYSTEMS& WIRING DIAGRAMS MANUALE TECNICO CITOFONICO E SCHEMARIO

Strona 46

48 TWO ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one on page 46 but has two entrances. The Art.502N (audio entrances

Strona 48 - SISTEMI CITOFONICI “1+1”

50 THREE OR MORE ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one on page 46 but has three entrances. The call from one

Strona 50

52 ONE ENTRANCE WITH PROXIMITY KEY READER AUDIO DOOR ENTRY SYSTEM FOR “20” USERS (FIG.1) The figure 1 diagram shows the basic system on page 46 addi

Strona 52

54 INTERCOMMUNICATING DOOR ENTRY SYSTEMS SISTEMI CITOFONICI INTECOMUNICANTI TWO USER INTERCOMMUNICATING SYSTEM The diagram on figure “A” shows a t

Strona 54

56 FIVE USERS INTERCOMMUNICATING SYSTEM WITHOUT OUTDOOR STATION The diagram shows an intercommunicating system which uses five push button intercoms

Strona 57

58 FIVE USERS INTERCOMMUNICATING SYSTEM WITH ONE ENTRANCE The diagram shows the installation of page 56 complete with the outdoor station. Operatio

Strona 59

60 FIVE USERS INTERCOMMUNICATING SYSTEM WITH TWO ENTRANCES The installation shown on the diagram works like the one on page 58 but has two entrances

Strona 61

62 FIVE USERS INTERCOMMUNICATING SYSTEM WITH THREE ENTRANCES The installation shown on the diagram works like the one on page 58 but has three or mo

Strona 63

64 See page 66 for system description. Vedi pagina 66 per la descrizione dell’impianto. ONE MAIN ENTRANCE PLUS THREE SECONDARY ENTRANCES AUDIO DOOR

Strona 64

65See page 66 for system description. Vedi pagina 66 per la descrizione dell’impianto.

Strona 65

66 “3+1” AUDIO DOOR ENTRY SYSTEMS SISTEMI CITOFONICI “3+1” ONE MAIN ENTRANCE PLUS THREE SECONDARY ENTRANCES AUDIO DOOR ENTRY SYSTEM The diagram sho

Strona 66

67NOTES NOTE

Strona 67

5INTRODUCTION INTRODUZIONE The VIDEX products described in this manual can be used to make audio door phone systems to satisfy all needs. The full r

Strona 68

68 NOTES NOTE

Strona 71

6 INTERCOMS CITOFONI FOR “3+1” & “4+1” SYSTEMS PER SISTEMI “3+1” E “4+1” Art.3101 Intercom made from white ABS shockproof plastic with “door-o

Strona 72

7Terminals: 4 Electronic call tone input 6 Unused 2 Speech line input from outdoor station microphone to handset speaker Speech line output from han