Videx SENTRY Instrukcja Użytkownika Strona 8

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 7
PAGE 6 of 29 SENTRY TECHNICAL MANUAL VER1.6
INTERCOM 3 PCB
NOTE
In the event of the speech needing to be adjusted to eliminate feedback or to increase the
speech volume to an acceptable level the following two options are available :-
Option 1. The speech can be adjusted at the door panel amplifier by adjusting the two
volume controls (One for transmitting to the apartment and one for receiving from the
apartment).
Option 2. There is also a volume POT [VR1] on the intercom 3 PCB. This will adjust both
directions of speech at the same time and is only intended for situations when the volume
cannot be adjusted sufficiently at the door panel. (Note: This will also adjust the call tone
volume both at the door and at the apartment station).
1
2
3
CN1 Connections in from Sentry PCB
CN2 Connections out to apartment station
Volume adjust
1
2
3
The intercom 3 apartment station
interface PCB is required whenever
the 500, 500M or 500ST apartment
station are used. This PCB converts
the duplex speech into simplex
speech and controls the switching of
the apartment station
CON Terminal Function
CN1
+12V +12Vdc In
Gnd Ground
3 Switched 12Vdc
4 Calltone
2 Receive Speech
1 Transmit Speech
5 Lock Trigger
CN2
1 Lock button
6 Talk button
2 Switched 12Vdc
3 Speaker
5 Ground
+12V +12Vdc Out
Przeglądanie stron 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 31 32

Komentarze do niniejszej Instrukcji

Brak uwag