PAGE 6 of 68 VX2200 TECHNICAL MANUAL VER1.5
VOLUME ADJUSTMENT
There are four volume adjusters on the door panel as follows:-
Speaker volume Microphone volume Balance between mic Voice annunciation
volume and speaker volume (May also be
volume labelled ‘V.PB CHIP’
MAKING A CALL
All stages of the call will be acknowledged via the LCD display, voice annunciation and call progress tones.
Additionally, the panel will also prompt the user with information on how to progress to the next stage of the
call. To make a call simply enter the apartment number required and press ‘Enter’. Alternatively, if the panel
has the scroll buttons (‘’,’’,’’) use the ‘’, ‘’ to locate the apartment to call then press ‘’.
USING THE TRADE
On the 4000 Series and 8000 Series panels the
trade feature can only be used with a code. To use
this facility first the TRD connection must to shorted
to ground (As shown in the diagram to the right).
To enter a trade code the panel must be in
standby. Press the clear button (Display will show
‘TRADE C’), enter the code and then press ‘Enter’.
On the vandal resistant panel the trade button can be used as described above or alternatively the trade
button can be used to simply release the door when the button is pressed (As long as the time clock is
active). See diagram below for wiring these options.
WITHOUT CODE WITH CODE
USING AN ACCESS CODE AND ENTERING PROGRAMMING MODE
On panels with a ‘CODE’ button, press ‘CODE’ followed by the code and press ‘Enter’. For panels without a
‘CODE’ button, press ‘0’ followed by the code and press ‘Enter’
Technical specifications
Memory capacity : 998 users
Working voltage : 13 Vdc +/- 10%
Max. absorption : about 350 mA
Working temperature : -10 +50 C°
Relay contacts : 3A@30Vdc, 3A@120Vac