Przeglądanie stron 24
LU
CPU
Art.3171 or Ar
t.3172
Telephones
4 way junction box
Landing Unit
SP400 control cabinet
VX2200 digital or
functional door panel
12Vdc fail secure or fail
open lock release
Product Key
VX2200 Block Diagram
1 main audio entrance and multiple block audio entrances to multiple
apartments using Art.3171 or Art.3172 telephones
VIDEX SECURITY LTD, UNIT 4-7 CHILLINGHAM IND. EST., NEWCASTLE
UPON TYNE, NE6 2XX
TEL 0870 300 1240 FAX 0191 224 5678 E-MAIL SALES@VIDEX-
SECURITY.COM WEB WWW.VIDEX-SECURITY.COM
CPU
2
6
4
CPUa
SP400 control cabinet
with 2206A bus
exchange device
CPUa
LU
LU
2
2
2
2
2
2
6
2
CPUa
LU
LU
2
2
2
2
2
2
6
2
4
Block 1
Block 2
Main entrance or gate
Min. cable requirements
Max. distance 100m
1 Pair
AWG22 (0.325mm²)
Resistance/km 54.12Ω
6 Pair
AWG22 (0.325mm²)
Resistance/km 54.12Ω
Max. distance 200m
1 Pair
AWG20 (0.5mm²)
Resistance/km 32.8Ω
6 Pair
AWG20 (0.5mm²)
Resistance/km 32.8Ω
Max. distance 350m
1 Pair
AWG18 (0.8mm²)
Resistance/km 19.2Ω
6 Pair
AWG18 (0.8mm²)
Resistance/km 19.2Ω
Consult the VX2200 cable guide for
more information
4
2
2
4
2
4
Notes:
Two extra cores required to the telephone’s if
the local door bell facility is required (Not
available on isolation systems)
6
6
6