Videx VX2200 Instrukcja Naprawy Strona 35

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 34
PAGE 35 of 60 VX2200 TECHNICAL MANUAL VER1.4
Programming
Programming is carried out by setting the internal 8 way dip-switch to the positions shown on the
decimal/binary conversion table of this manual.
Additional programming options include:
Programming the Melodies (factory preset melody 1)
Press and hold the two melody buttons “
” (for approx 10 seconds) until the unit plays the current
stored melody and emits a beep.
Press the melody button again (left or right) to listen to the available melodies (maximum 9).
When the chosen melody has been reached, do not press any buttons wait 3 seconds for the exit
beep.
The new melody is now stored.
Programming the Number of Rings (factory preset = 6 rings)
Press and hold the “
” button (for approx 10 seconds) until the unit emits a beep.
Press the “
” button as many times as the number of rings required (i.e. 6 presses = 6 rings with a
maximum of 9 rings)
Once the number of rings required has been reached, wait 3 seconds for the exit beep.
The new value is now stored.
Programming the Privacy duration (factory preset = without time out)
Press and hold the “
” button (for approx 10 seconds) until the unit emits a beep.
Press the “
” button again to set the privacy duration. Each time the button is pressed, it will
increase the privacy duration by 15 minutes (starting from 0 up to a maximum of 20 hours i.e.
pressing the button 8 times = 2 hours up to a maximum of 80 presses for 20 hours). Once the
required privacy duration has been reached, wait 3 seconds for the exit beep.To set the privacy with
no time out Press and hold the “
” button (for approx 10 seconds) until the unit emits a beep do not
press any other button wait 3 seconds for the exit beep.
The new value is now stored.
Restore to factory defaults
Power up the intercom keeping pressed the “
” button;
The intercom will emit a beep to confirm the operation;
Release the “
” button.
Technical Specifications
Addressing range : from 1 to 180 (BIN code)
Working voltage : 12Vdc
Stand-by absorption : about 6mA
Phone max. absorption : about 50mA
Working temperature : -10 +50 C°